Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

An experimentally-accurate and complete room-temperature infrared HCN line-list for the HITRAN database

Title: An experimentally-accurate and complete room-temperature infrared HCN line-list for the HITRAN database
Authors: Mellau, GC; Makhnev, VY; Gordon, IE; Zobov, NF; Tennyson, J; Polyansky, OL
Source: Journal of Quantitative Spectroscopy and Radiative Transfer , 270 , Article 107666. (2021)
Publication Year: 2021
Collection: University College London: UCL Discovery
Subject Terms: HCN; Hydrogen cyanide; Molecular spectra; Infrared spectra; HCN line list
Description: A hydrogen cyanide line list (MOMeNT-90) developed for the HITRAN spectroscopic database covering 0–7500 cm−1 range (λ>1330 nm) is presented. The line list is a combination of the variationally calculated line intensities with line centers obtained from experimentally derived energy levels. There are four features of this line list which distinguishes it from the previously calculated ones. First, the intensities are variationally calculated using a new, high-accuracy potential energy surface (PES) obtained via fitting the PES using experimental energy levels. Second, a new ab initio dipole moment surface was calculated at a high level of quantum chemical theory. Based on the wave functions calculated with the new PES and use of the new dipole moment surface, line intensities are reported which of similar accuracy to those obtained experimentally. Third, the calculated states are mapped to the existing complete set of experimental eigenenergies, resulting in an assigned and complete HCN line list down to the HITRAN intensity threshold of 10−34 cm/molecule. Fourth, extensive validation of the line list is provided through line-by-line comparisons of the results with measured HCN spectra which confirms the accuracy of the intensities used to construct the line list. The line list is augmented with parameters needed to calculate line widths for pressure-dependent simulations.
Document Type: article in journal/newspaper
File Description: text
Language: English
Relation: https://discovery.ucl.ac.uk/id/eprint/10130567/1/HCN_LineList.pdf; https://discovery.ucl.ac.uk/id/eprint/10130567/
Availability: https://discovery.ucl.ac.uk/id/eprint/10130567/1/HCN_LineList.pdf; https://discovery.ucl.ac.uk/id/eprint/10130567/
Rights: open
Accession Number: edsbas.1CD4EE10
Database: BASE