Global prospective case series of ERCPs using a single-use duodenoscope

Title: Global prospective case series of ERCPs using a single-use duodenoscope
Authors: Bruno, MJ; Beyna, T; Carr-Locke, D; Chahal, P; Costamagna, G; Devereaux, B; Giovannini, M; Goenka, MK; Khor, C; Lau, J; May, G; Muthusamy, VR; Patel, S; Petersen, BT; Pleskow, DK; Raijman, I; Reddy, DN; Repici, A; Ross, AS; Sejpal, DV; Sherman, S; Siddiqui, UD; Ziady, C; Peetermans, JA; Rousseau, MJ; Slivka, A
Source: Bruno, MJ, Beyna, T, EXALT Single-use Duodenoscope Study Group, Carr-Locke, D, Chahal, P, Costamagna, G, Devereaux, B, Giovannini, M, Goenka, MK, Khor, C, Lau, J, May, G, Muthusamy, VR, Patel, S, Petersen, BT, Pleskow, DK, Raijman, I, Reddy, DN, Repici, A, Ross, AS, Sejpal, DV, Sherman, S, Siddiqui, UD, Ziady, C, Peetermans, JA, Rousseau, MJ & Slivka, A 2023, 'Global prospective case series of ERCPs using a single-use duodenoscope', Endoscopy, vol. 55, no. 12, pp. 1103-1114. https://doi.org/10.1055/a-2131-7180
Publication Year: 2023
Description: Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ? 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged >65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3 4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.
Document Type: article in journal/newspaper
File Description: application/pdf
Language: English
ISSN: 0013-726X; 1438-8812
Relation: info:eu-repo/semantics/altIdentifier/pmid/37463599; info:eu-repo/semantics/altIdentifier/wos/001072764500001; info:eu-repo/semantics/altIdentifier/pissn/0013-726X; info:eu-repo/semantics/altIdentifier/eissn/1438-8812
DOI: 10.1055/a-2131-7180
Availability: https://pure.eur.nl/en/publications/1b46d930-192d-4c12-b366-52edb2415612; https://doi.org/10.1055/a-2131-7180; https://pure.eur.nl/ws/files/103696322/a-2131-7180.pdf; https://www.scopus.com/pages/publications/85173504538
Rights: info:eu-repo/semantics/openAccess ; http://creativecommons.org/licenses/by/4.0/
Accession Number: edsbas.1F34F4A1
Database: BASE