Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Determination of Vitamin B12 in Infant, Adult, and Pediatric Formulas by HPLC-UV and Column Switching: Collaborative Study, Final Action 2011.10

Title: Determination of Vitamin B12 in Infant, Adult, and Pediatric Formulas by HPLC-UV and Column Switching: Collaborative Study, Final Action 2011.10
Authors: Butler-Thompson, Linda D; Jacobs, Wesley A; Schimpf, Karen J; Austad, J; Chen, B; Christiansen, S; Domer, C; Hostetler, G; Labitan, D; Liu, B; Malaviole, I; Marosanović, B; Martin, F; Mittal, A; Oberson, J M; Ruosch, A; Shen, Y; Wang, G
Source: Journal of AOAC INTERNATIONAL ; volume 98, issue 6, page 1655-1665 ; ISSN 1060-3271 1944-7922
Publisher Information: Oxford University Press (OUP)
Publication Year: 2015
Description: AOAC First Action Method 2011.10, Vitamin B12 in Infant and Pediatric Formulas and Adult Nutritionals, was collaboratively studied. This method uses a pH 4.5 sodium acetate buffer and potassium cyanide at 105°C to extract and convert all biologically active forms of vitamin B12 present to cyanocobalamin; octylsilyl (C8) or C18 SPE cartridges to purify and concentrate cyanocobalamin; a combination of size-exclusion and RPLC to isolate cyanocobalamin; and visible absorbance at 550 nm to detect and quantitate cyanocobalamin in infant, pediatric, and adult nutritionals with vitamin B12 concentrations greater than 0.025 μg/100 g ready-to-feed (RTF) liquid. During this collaborative study, nine to 11 laboratories from eight different countries analyzed blind duplicates of 12 infant, pediatric, and adult nutritional formulas. Per the AOAC Expert Review Panel (ERP) on Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) Nutrient Methods the method demonstrated acceptable repeatability and reproducibility and met SPIFAN Standard Method Performance Requirements (SMPRs®) for the majority of product matrixes analyzed. Vitamin B12 SPIFAN SMPRs for repeatability were ≤15% RSD at vitamin B12 concentrations of 0.01 μg/100 g RTF liquid and ≤7% RSD at vitamin B12 concentrations of 0.2–5.0 μg/100 g RTF liquid. Vitamin B12 SPIFAN SMPRs for reproducibility were ≤11% RSD in products with vitamin B12 concentrations ranging from 0.3 to 5.0 μg/100 g RTF liquid. During this collaborative study, the RSDr ranged from 2.98 to 9.77%, and the RSDR ranged from 3.54 to 19.5%. During previous single-laboratory validation studies, the method LOQ was estimated to be 0.025 μg/100 g RTF liquid.
Document Type: article in journal/newspaper
Language: English
DOI: 10.5740/jaoacint.15-108
Availability: https://doi.org/10.5740/jaoacint.15-108; http://academic.oup.com/jaoac/article-pdf/98/6/1655/32424762/jaoac1655.pdf
Rights: https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model
Accession Number: edsbas.1F459E4D
Database: BASE