Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Multicenter Evaluation of the QIAstat‐Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens

Title: Multicenter Evaluation of the QIAstat‐Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens
Authors: Gosert, Rainer; Koller, Roger; Meyer, Jakob; Dräger, Sarah; Ramette, Alban; Bingisser, Roland; Nickel, Christian H.; Bassetti, Stefano; Sutter, Sarah Tschudin; Keller, Peter M.; Bittel, Pascal; Leuzinger, Karoline
Source: Journal of Medical Virology ; volume 96, issue 12 ; ISSN 0146-6615 1096-9071
Publisher Information: Wiley
Publication Year: 2024
Collection: Wiley Online Library (Open Access Articles via Crossref)
Description: Syndromic multiplex panel testing enables simultaneous detection of multiple respiratory pathogens, but limited data is available on the comparative diagnostic performance of different testing systems. In this multicenter prospective study, we aimed to compare the QIAstat‐Dx Respiratory Panel 2.0 (QIAstat‐Dx‐RP2.0) with the widely used BioFire‐RP2.1, using 269 respiratory clinical specimens. Concordant test results were obtained in 232 (86.3%) cases. Discordant test results included 33 BioFire‐RP2.1(+)/QIAstat‐Dx‐RP2.0(−) and 4 BioFire‐RP2.1(‐)/QIAstat‐Dx‐RP2.0(+) results. Discordant samples showed significantly lower pathogen loads than concordant ones ( p < 0.01). Overall, the QIAstat‐Dx‐RP2.0 showed an analytical sensitivity of 50%–100% depending on the respiratory target, with an analytical specificity ≥ 99.0%. Most significant differences were found for the detection of adenovirus, human coronaviruses, respiratory syncytial virus, human rhinovirus/enterovirus and SARS‐CoV‐2 (kappa‐score: 0.67–0.91). Co‐detections of respiratory pathogens were identified in 47 cases by BioFire‐RP2.1 and 29 by QIAstat‐Dx‐RP2.0. Agreement rates between the two multiplex panel tests decreased from 91.8% for single pathogen detections to 65.0% and 42.9% for co‐detecting two and three pathogens, respectively. Pathogen loads were significantly lower in co‐detections compared to single pathogen detections ( p < 0.01), potentially explaining the lower detection rates with the QIAstat‐Dx‐RP2.0 in cases of multiple pathogens. In conclusion, our prospective multicenter evaluation showed good diagnostic performance of the QIAstat‐Dx‐RP2.0 assay, but lower detection rates for some respiratory targets compared to BioFire‐RP2.1. As QIAstat‐Dx‐RP2.0 offers advantages in handling, noise emission, cost effectiveness, and provides semi‐quantitative results compared to BioFire‐RP2.1 an updated version with enhanced analytical sensitivity would be a viable alternative syndromic testing system for detecting respiratory pathogens.
Document Type: article in journal/newspaper
Language: English
DOI: 10.1002/jmv.70129
Availability: https://doi.org/10.1002/jmv.70129; https://onlinelibrary.wiley.com/doi/pdf/10.1002/jmv.70129
Rights: http://creativecommons.org/licenses/by-nc/4.0/
Accession Number: edsbas.270C5D6B
Database: BASE