Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Comparison of diagnostic performances of HDV-RNA quantification assays used in clinical practice: Results from a national quality control multicenter study

Title: Comparison of diagnostic performances of HDV-RNA quantification assays used in clinical practice: Results from a national quality control multicenter study
Authors: Salpini R.; Piermatteo L.; Caviglia G. P.; Bertoli A.; Brunetto M. R.; Bruzzone B.; Callegaro A.; Caudai C.; Cavallone D.; Chessa L.; Coghe F.; Coppola N.; Cuomo N.; D'Anna S.; Di Stefano M.; Facchetti F.; Farina C.; Ferraro D.; Franchin E.; Francisci D.; Galli S.; Garbuglia A. R.; Gennari W.; Ghisetti V.; Lampertico P.; Lo Caputo S.; Marascio N.; Menzo S.; Micheli V.; Niro G. A.; Olivero A.; Paba P.; Palermo C. I.; Palmieri O.; Paolucci S.; Pisaturo M.; Pollicino T.; Raffa G.; Santantonio T.; Torre G.; Turriziani O.; Uzzau S.; Uceda Renteria S. C.; Vatteroni M.; Zazzi M.; Craxi A.; Ceccherini-Silberstein F.; Svicher V.; Arosio M.; Bastianelli S.; Gentile A.; Giardina F. A. M.; Gidari A.; Govoni R.; Ibba G.; Loglio A.; Lombardi A.; Mascarella C.; Maggi F.; Matera G.; Mazzei C.; Milia M. G.; Quirino A.; Raddi A.; Scioscia R.; Tagliazucchi S.; Totaro M.; Valaperta R.
Contributors: Salpini, R.; Piermatteo, L.; Caviglia, G. P.; Bertoli, A.; Brunetto, M. R.; Bruzzone, B.; Callegaro, A.; Caudai, C.; Cavallone, D.; Chessa, L.; Coghe, F.; Coppola, N.; Cuomo, N.; D'Anna, S.; Di Stefano, M.; Facchetti, F.; Farina, C.; Ferraro, D.; Franchin, E.; Francisci, D.; Galli, S.; Garbuglia, A. R.; Gennari, W.; Ghisetti, V.; Lampertico, P.; Lo Caputo, S.; Marascio, N.; Menzo, S.; Micheli, V.; Niro, G. A.; Olivero, A.; Paba, P.; Palermo, C. I.; Palmieri, O.; Paolucci, S.; Pisaturo, M.; Pollicino, T.; Raffa, G.; Santantonio, T.; Torre, G.; Turriziani, O.; Uzzau, S.; Uceda Renteria, S. C.; Vatteroni, M.; Zazzi, M.; Craxi, A.; Ceccherini-Silberstein, F.; Svicher, V.; Arosio, M.; Bastianelli, S.; Gentile, A.; Giardina, F. A. M.; Gidari, A.; Govoni, R.; Ibba, G.; Loglio, A.; Lombardi, A.; Mascarella, C.; Maggi, F.; Matera, G.; Mazzei, C.; Milia, M. G.; Quirino, A.; Raddi, A.; Scioscia, R.; Tagliazucchi, S.; Totaro, M.; Valaperta, R.
Publication Year: 2025
Collection: Università degli Studi di Cagliari: UNICA IRIS
Subject Terms: HDV-RNA; Hepatitis D; Real-Time PCR
Description: Introduction: A reliable quantification of hepatitis D virus (HDV) RNA is of paramount importance for monitoring patients under antiviral therapy. This quality control study compares the diagnostic performances of quantitative HDV-RNA assays used in clinical practice. Methods: Two HDV-RNA sample panels were quantified in 30 centers by RoboGene (N = 9 laboratories), EurobioPlex (N = 7), RealStar (N = 4), AltoStar (N = 1), Bosphore (N = 3), Bosphore-on-InGenius (N = 1), Dia.Pro (N = 2), Nuclear-Laser-Medicine (N = 1) and 3 in-house assays. Panel A and B comprised 8 serial dilutions of WHO/HDV standard (range: 0.5–5.0 log10 IU/ml) and 20 clinical samples (range: 0.5–6.0 log10 IU/ml), respectively. The following parameters were determined: sensitivity by 95 % LOD (limit of detection), precision by intra- and inter-run CV (coefficient of variation), accuracy by the differences between expected-observed HDV-RNA, linearity by linear regression analysis. Results: 95 % LOD varied across assays and centers underlining heterogeneous sensitivities: AltoStar had the lowest 95 % LOD (3 IU/ml) followed by RealStar (10 [min–max: 3–316] IU/ml), Bosphore-on-InGenius (10 IU/ml), RoboGene (31 [3–316] IU/ml), Nuclear-Laser-Medicine (31 IU/ml) and EuroBioplex (100 [100–316] IU/ml). Moreover, 6 assays (RoboGene, EurobioPlex, RealStar, AltoStar, Nuclear-Laser-Medicine and In-house) showed 1 log10 IU/ml underestimations. RealStar, Bosphore-on-InGenius and EurobioPlex had the highest precision (mean intra-run CV < 20 %). Inter-run CV was higher for all assays, with CVs < 25 % for RealStar, AltoStar, Nuclear-Laser-Medicine and EurobioPlex. Seven assays (RoboGene/AltoStar/RealStar/EurobioPlex/Nuclear-Laser-Medicine/In-house) showed a good linearity (R2 > 0.90), but for HDV-RNA < 1000 IU/ml only Bosphore-on-InGenius, AltoStar, RealStar and Robogene showed a R2 > 0.85. Conclusions: This study underlines ...
Document Type: article in journal/newspaper
Language: English
Relation: info:eu-repo/semantics/altIdentifier/pmid/40784197; info:eu-repo/semantics/altIdentifier/wos/WOS:001583952700002; volume:180; journal:JOURNAL OF CLINICAL VIROLOGY; https://hdl.handle.net/11584/451265
DOI: 10.1016/j.jcv.2025.105850
Availability: https://hdl.handle.net/11584/451265; https://doi.org/10.1016/j.jcv.2025.105850
Rights: info:eu-repo/semantics/openAccess
Accession Number: edsbas.2B2D2C2
Database: BASE