Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

Title: Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X
Authors: W7-X Team; Pandey, A.; Bohm, S.; Carls, A.; Cordes, C.; Endler, M.; Fellinger, J.; Freundt, S.; Gallowski, K.; Hammond, K.; Hathiramani, D.; Isberner, G.; Kallmeyer, J. P.; Krause, M.; Kügler, J.; Otte, M.; Pedersen, T. S.; Rondeshagen, D.; Ruhnau, J.; Schröder, T.; Sieber, T.; Wendorf, J.
Source: Review of Scientific Instruments, 95 (4), Article no: 043503 ; ISSN: 0034-6748, 1089-7623
Publisher Information: American Institute of Physics
Publication Year: 2024
Collection: KITopen (Karlsruhe Institute of Technologie)
Subject Terms: ddc:600; Technology; info:eu-repo/classification/ddc/600
Description: The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.
Document Type: article in journal/newspaper
File Description: application/pdf
Language: English
ISSN: 0034-6748; 1089-7623
Relation: info:eu-repo/grantAgreement/EC/EURATOM/101052200/EU//EUROfusion; info:eu-repo/semantics/altIdentifier/wos/001195794300007; info:eu-repo/semantics/altIdentifier/issn/0034-6748; info:eu-repo/semantics/altIdentifier/issn/1089-7623; https://publikationen.bibliothek.kit.edu/1000170663; https://publikationen.bibliothek.kit.edu/1000170663/152856591; https://doi.org/10.5445/IR/1000170663
DOI: 10.5445/IR/1000170663
Availability: https://publikationen.bibliothek.kit.edu/1000170663; https://publikationen.bibliothek.kit.edu/1000170663/152856591; https://doi.org/10.5445/IR/1000170663
Rights: https://creativecommons.org/licenses/by/4.0/deed.de ; info:eu-repo/semantics/openAccess