Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Effect of a Contrast Agent on Bone Mineral Density Measurement in the Spine and Hip Using QCT-Conversion Factor Recommendation

Title: Effect of a Contrast Agent on Bone Mineral Density Measurement in the Spine and Hip Using QCT-Conversion Factor Recommendation
Authors: Jäckle, Katharina; Lüken, Sophia; Roch, Paul Jonathan; Klockner, Friederike Sophie; Reinhold, Max; Meier, Marc-Pascal; Hawellek, Thelonius; Lehmann, Wolfgang; Weiser, Lukas; 1Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
Contributors: Jäckle, Katharina; Lüken, Sophia; Roch, Paul Jonathan; Klockner, Friederike Sophie; Reinhold, Max; Meier, Marc-Pascal; Hawellek, Thelonius; Lehmann, Wolfgang; Weiser, Lukas; 1Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
Publication Year: 2023
Collection: Georg-August-Universität Göttingen: GoeScholar
Description: Background: Osteoporosis causes an increased fracture risk. Clinically, osteoporosis is diagnosed late, usually after the first fracture occurs. This emphasizes the need for an early diagnosis of osteoporosis. However, computed tomography (CT) as routinely used for polytrauma scans cannot be used in the form of quantitative computed tomography (QCT) diagnosis because QCT can only be applied natively, i.e., without any contrast agent application. Here, we tested whether and how contrast agent application could be used for bone densitometry measurements. Methods: Bone mineral density (BMD) was determined by QCT in the spine region of patients with and without the contrast agent Imeron 350. Corresponding scans were performed in the hip region to evaluate possible location-specific differences. Results: Measurements with and without contrast agent administration between spine and hip bones indicate that the corresponding BMD values were reproducibly different between spine and hips, indicating that Imeron 350 application has a location-specific effect. We determined location-specific conversion factors that allow us then to determine the BMD values relevant for osteoporosis diagnosis. Conclusions: Results show that contrast administration cannot be used directly for CT diagnostics because the agent significantly alters BMD values. However, location-specific conversion factors can be established, which are likely to depend on additional parameters such as the weight and corresponding BMI of the patient. ; Open Access Publication Funds of the Göttingen University ; Open-Access-Publikationsfonds 2023