Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

Title: Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study
Authors: Bernert, John T.; Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.
Publisher Information: Oxford University Press
Publication Year: 2009
Collection: HighWire Press (Stanford University)
Subject Terms: Original Investigation
Description: Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range.
Document Type: text
File Description: text/html
Language: English
Relation: http://ntr.oxfordjournals.org/cgi/content/short/ntp161v1; http://dx.doi.org/10.1093/ntr/ntp161
DOI: 10.1093/ntr/ntp161
Availability: http://ntr.oxfordjournals.org/cgi/content/short/ntp161v1; https://doi.org/10.1093/ntr/ntp161
Rights: Copyright (C) 2009, Society for Research on Nicotine and Tobacco
Accession Number: edsbas.354C57F7
Database: BASE