Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

A trial evaluating mid cut-off value membrane clearance of albumin and light chains in hemodialysis patients: A safety device study

Title: A trial evaluating mid cut-off value membrane clearance of albumin and light chains in hemodialysis patients: A safety device study
Authors: Krishnasamy, R; Hawley, CM; Jardine, MJ; Roberts, MA; Cho, Y; Wong, M; Heath, A; Nelson, CL; Sen, S; Mount, PF; Pascoe, EM; Vergara, LA; Paul-Brent, PA; Toussaint, ND; Johnson, DW; Hutchison, CA
Source: urn:ISSN:0253-5068 ; urn:ISSN:1421-9735 ; Blood Purification, 49, 4, 468-478
Publisher Information: Karger Publishers
Publication Year: 2020
Collection: UNSW Sydney (The University of New South Wales): UNSWorks
Subject Terms: 32 Biomedical and Clinical Sciences; 3202 Clinical Sciences; Kidney Disease; Assistive Technology; Clinical Trials and Supportive Activities; Clinical Research; Bioengineering; 2 Zero Hunger; Adult; Aged; Female; Humans; Immunoglobulin kappa-Chains; Immunoglobulin lambda-Chains; Male; Membranes; Artificial; Middle Aged; Quality of Life; Renal Dialysis; Serum Albumin; Human; Albumin; Dialysis membrane; Dialyzer; Efficacy; Free light chains; Hemodialysis; Mid cut-off; Safety
Description: Background: A new class of dialysis membrane, the mid cut-off (MCO) dialyzer, has been developed to improve the clearance of uremic toxins in hemodialysis (HD). The a tRial Evaluating Mid cut-Off Value membrane clearance of Albumin and Light chains in HemoDialysis patients (REMOVAL-HD) study aimed to determine if regular use of MCO dialyzer was safe and specifically did not result in a significant loss of albumin. Methods: This investigator initiated, crossover, longitudinal, device study was conducted across 9 centers in Australia and New Zealand (n = 89). Participants had a 4-week wash-in with high-flux HD, followed by 24-week intervention with MCO HD and a subsequent 4-week wash-out with high-flux HD. The primary outcome was change in serum albumin between weeks 4 and 28. Secondary outcomes included trends in serum albumin, changes in kappa-and lambda-free light chains (FLC), 6-min walk test (6MWT), malnutrition inflammation score (MIS), restless legs score and quality of life. Results: Participants had a mean age of 66 ± 14 years, 62% were men, 45% were anuric, and 51% had-diabetes. There was no reduction in serum albumin following treatment with MCO HD (mean reduction-0.7 g/L, 95% CI-1.5 to 0.1). A sustained, unexplained reduction in serum albumin (>25%) was not observed in any participant. A reduction in FLC was observed 2 weeks into MCO HD (lambda-FLC: Δ-9.1 mg/L, 95% CI-14.4 to-3.7; kappa-FLC: Δ-5.7 mg/L, 95% CI-9.8 to-1.6) and was sustained for the rest of the study intervention. Both FLC increased after the cessation of MCO use. There was no improvement in restless legs symptoms, quality of life, 6MWT or MIS scores. Conclusions: Regular HD using the MCO dialyzer did not result in a significant fall in serum albumin. There were no effects on quality of life, functional status or nutrition. Trial Registration: Australian New Zealand Clinical Trials Registry Number (ANZCTRN) 12616000804482.
Document Type: article in journal/newspaper
File Description: application/pdf
Language: unknown
Relation: https://hdl.handle.net/1959.4/unsworks_66368; https://doi.org/10.1159/000505567
DOI: 10.1159/000505567
Availability: https://hdl.handle.net/1959.4/unsworks_66368; https://unsworks.unsw.edu.au/bitstreams/dd2a9975-e6b7-4f7d-87bb-d8d7990336fa/download; https://doi.org/10.1159/000505567
Rights: open access ; https://purl.org/coar/access_right/c_abf2 ; CC-BY-NC-ND ; https://creativecommons.org/licenses/by-nc-nd/4.0/ ; free_to_read
Accession Number: edsbas.3664548D
Database: BASE