New battery model for consolidating a health monitoring system model of reusable launcher power harness

Title: New battery model for consolidating a health monitoring system model of reusable launcher power harness
Authors: Cartron, Mickaël; Slimani, Mariem; Gregis, Nicolas; Monchaux, David; Besson, Dominique
Contributors: Laboratoire Fiabilité et Intégration de Capteurs (CEA, LIST) (LFIC (CEA, LIST)); Département Métrologie Instrumentation & Information (CEA, LIST) (DM2I (CEA, LIST)); Laboratoire d'Intégration des Systèmes et des Technologies (LIST (CEA)); Direction de Recherche Technologique (CEA) (DRT (CEA)); Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Direction de Recherche Technologique (CEA) (DRT (CEA)); Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Laboratoire d'Intégration des Systèmes et des Technologies (LIST (CEA)); Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay; Centre National d’Études Spatiales Paris (CNES)
Source: IAC 2022 - 73rd International Astronautical Conference ; https://cea.hal.science/cea-04239532 ; IAC 2022 - 73rd International Astronautical Conference, Sep 2022, Paris, France. , 2022 ; https://iac2022.org/
Publisher Information: CCSD
Publication Year: 2022
Subject Terms: system integrity; simulation; power consumption peak; impedance variation; sensor; cable chafing; intermittent fault; defect; connector; cable; maintenance; reliability; instrumentation; monitoring; reusable launcher; electrical harness; reflectometry; modeling; health monitoring; Battery; [INFO.INFO-AR]Computer Science [cs]/Hardware Architecture [cs.AR]; [SPI.OTHER]Engineering Sciences [physics]/Other
Subject Geographic: Paris; France
Description: International audience ; Being able to monitor the state of health of reusable launcher systems is a major concern. A health monitoring system (HMS) should provide a reliable information on the system's integrity and guide the maintenance process with the most accurate information possible, in the shortest possible time, with the smallest possible overhead in terms of size, weight and power consumption (SWaP).Electrical harnesses are critical components, and several failures implying this function were already reported in launchers history. Cables and connectors are deployed through long ducts and are subject to high temperature gradients, and eventually, to chafing. In a previous work, we presented a reflectometry system aiming to monitor the health status of the power harness of a reusable launcher. A reflectometer is able to sense impedance variations in a propagation channel which can be due to several causes such as an intermittent fault in the harness causing a short/open circuit, soft defect due to harsh environmental conditions, but it can also be caused by normal changes within the system, for example during high current peaks.The monitoring system should be as sensitive as possible, but with as few false alarms as possible. This study's goal is to ensure that the presence of batteries will not cause false alarms in the system especially during power consumption peaks. In a first part, we give details about the mission, and more specifically about the power harness. The use case is completed by the description of a representative battery pack suitable for such a mission.Then, we characterize the representative battery pack, exploring the following parameters: the remaining energy and the instantaneous current. For that, we realized a dedicated measurement bench to extract the complex impedance of the battery when delivering a specific current.Then, in a third part, we inject the battery model, characterized by its complex impedance, in the model of harness, and simulate reflectometry measurements on it. ...
Document Type: conference object; still image
Language: English
Availability: https://cea.hal.science/cea-04239532; https://cea.hal.science/cea-04239532v1/document; https://cea.hal.science/cea-04239532v1/file/Paper_IAC_2022_version1.pdf; https://cea.hal.science/cea-04239532v1/file/poster_MickaelCartron.jpg
Rights: info:eu-repo/semantics/OpenAccess
Accession Number: edsbas.4424A30E