Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Harmonization of Methods for Analysis of Cholesterol Oxides in Foods—The First Portion of a Long Road Toward Standardization: Interlaboratory Study

Title: Harmonization of Methods for Analysis of Cholesterol Oxides in Foods—The First Portion of a Long Road Toward Standardization: Interlaboratory Study
Authors: Appelqvist, Lars-Åke; Addis, Paul; Björkhem, Ingemar; Olivier Bosset, Jacques; Fiorenza Caboni, Maria; Dutta, Paresh; Grandgirard, Andre; Guardiola, Fransesc; Hau, Lung-Bin; Holm Nielsen, Jacob; Hugget, Antony; Sun Hwang, Lucy; Kumpulainen, Jorma; McCluskey, Sinead; Ohshima, Toshiaki; Przbylski, Roman; Sevanian, Alex; Yan, Pearlly
Source: Journal of AOAC INTERNATIONAL ; volume 87, issue 2, page 511-519 ; ISSN 1060-3271 1944-7922
Publisher Information: Oxford University Press (OUP)
Publication Year: 2004
Description: A compilation of literature data on the content of cholesterol oxidation products (COP) in various food products and in blood demonstrates a large variation in content in products or tissues of very similar nature when analyzed in different laboratories according to a large number of methods. The lack of validated, internationally recognized methodology with published accuracy and precision has so far hindered such assessments. Hence an interlaboratory comparision of methodologies of COP analysis was undertaken on egg yolk powders (EYP), whole milk powders (WMP), skim milk powders (SMP), and lard (L). Each product type had one fresh sample (low) and one aged (high) in COP contents. A total of 17 sets of results on WMP, 15 on SMP and EYP, and 13 on L were compared. Overall results (mg/kg sample) varied extensively: Fresh EYP 0.72–265, aged EYP 2.51–361; fresh WMP 0.02–18.1, aged WMP 0.02–26.9; fresh SMP 0.02–6.51, aged SMP < 0.01–6.51; fresh L 0.18–97, aged L 4.15–452. Some results were questioned, viz., those from laboratories not indicating substantial differences between samples “low” and “high” in total COP. Others were excluded because of lack of verification of identity of gas chromato-graphic peaks by mass spectrometry. Then a more narrow range of core results (mg/kg sample) was observed: Fresh EYP 5.69–29.5 sample, aged EYP 11.8–79.0; fresh WMP 0.12–1.76, aged WMP 1.17–13.7; fresh SMP < 0.30–
Document Type: article in journal/newspaper
Language: English
DOI: 10.1093/jaoac/87.2.511
Availability: https://doi.org/10.1093/jaoac/87.2.511; http://academic.oup.com/jaoac/article-pdf/87/2/511/32417908/jaoac0511.pdf
Rights: https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model
Accession Number: edsbas.4DEFC493
Database: BASE