Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Automated quantification of white matter disease extent at 3 T: comparison with volumetric readings

Title: Automated quantification of white matter disease extent at 3 T: comparison with volumetric readings
Authors: Hulsey, Keith M; Gupta, Mohit; King, Kevin S; Peshock, Ronald M; Whittemore, Anthony R; McColl, Roderick W
Source: Neuroradiology
Publisher Information: Barrow - St. Joseph's Scholarly Commons
Publication Year: 2012
Subject Terms: Algorithms; Brain (pathology); Demyelinating Diseases (pathology); Diffusion Tensor Imaging (methods); Humans; Image Enhancement (methods); Image Interpretation; Computer-Assisted (methods); Imaging; Three-Dimensional (methods); Nerve Fibers; Myelinated (pathology); Observer Variation; Pattern Recognition; Automated (methods); Reproducibility of Results; Sensitivity and Specificity
Description: PURPOSE: To develop and validate an algorithm to automatically quantify white matter hyperintensity (WMH) volume. MATERIALS AND METHODS: Images acquired as part of the Dallas Heart Study, a multiethnic, population-based study of cardiovascular health, were used to develop and validate the algorithm. 3D magnetization prepared rapid acquisition gradient echo (MP-RAGE) and 2D fluid-attenuated inversion recovery (FLAIR) images were acquired from 2082 participants. Images from 161 participants (7.7% of the cohort) were used to set an intensity threshold to maximize the agreement between the algorithm and a qualitative rating made by a radiologist. The resulting algorithm was run on the entire cohort and outlier analyses were used to refine the WMH volume measurement. The refined, automatic WMH burden estimate was then compared to manual quantitative measurements of WMH volume in 28 participants distributed across the range of volumes seen in the entire cohort. RESULTS: The algorithm showed good agreement with the volumetric readings of a trained analyst: the Spearman's Rank Order Correlation coefficient was r = 0.87. Linear regression analysis showed a good correlation WMHml[automated] = 1.02 × WMHml[manual] - 0.48. Bland-Altman analysis showed a bias of 0.34 mL and a standard deviation of 2.8 mL over a range of 0.13 to 41 mL. CONCLUSION: We have developed an algorithm that automatically estimates the volume of WMH burden using an MP-RAGE and a FLAIR image. This provides a tool for evaluating the WMH burden of large populations to investigate the relationship between WMH burden and other health factors.
Document Type: text
Language: unknown
Relation: https://scholar.barrowneuro.org/neuroradiology/38; https://doi.org/10.1002/jmri.23659
DOI: 10.1002/jmri.23659
Availability: https://scholar.barrowneuro.org/neuroradiology/38; https://doi.org/10.1002/jmri.23659
Accession Number: edsbas.570CEB30
Database: BASE