Performance of Subcutaneous Continuous Glucose Monitoring in Adult Critically Ill Patients Receiving Vasopressor Therapy

Title: Performance of Subcutaneous Continuous Glucose Monitoring in Adult Critically Ill Patients Receiving Vasopressor Therapy
Authors: Friman, Ola; Soltani, Navid; Lind, Marcus; Zetterqvist, Pia; Balintescu, Anca; Perner, Anders; Oldner, Anders; Rooyackers, Olav; Mårtensson, Johan
Source: Friman , O , Soltani , N , Lind , M , Zetterqvist , P , Balintescu , A , Perner , A , Oldner , A , Rooyackers , O & Mårtensson , J 2024 , ' Performance of Subcutaneous Continuous Glucose Monitoring in Adult Critically Ill Patients Receiving Vasopressor Therapy ' , Diabetes Technology and Therapeutics , vol. 26 , no. 10 , pp. 763-772 . https://doi.org/10.1089/dia.2024.0035
Publication Year: 2024
Collection: University of Copenhagen: Research / Forskning ved Københavns Universitet
Subject Terms: accuracy; continuous glucose monitoring; critical illness; diabetes
Description: Background: Subcutaneous continuous glucose monitoring (CGM) may facilitate glucose control in the ICU. We aimed to assess the accuracy of CGM (Dexcom G6) against arterial blood glucose (ABG) in adult critically ill patients receiving intravenous insulin infusion and vasopressor therapy. We also aimed to assess feasibility and tolerability of CGM in this setting. Methods: We included ICU patients receiving mechanical ventilation, insulin, and vasopressor therapy. Numerical accuracy was assessed by the mean absolute relative difference (MARD), overall, across arterial glucose strata, over different noradrenaline equivalent infusion rates, and over time since CGM start. MARD
Document Type: article in journal/newspaper
File Description: application/pdf
Language: English
DOI: 10.1089/dia.2024.0035
Availability: https://researchprofiles.ku.dk/da/publications/92f32b69-2a81-4c7f-80c1-e3c59c711f9d; https://doi.org/10.1089/dia.2024.0035; https://curis.ku.dk/ws/files/411758345/friman_et_al_2024_performance_of_subcutaneous_continuous_glucose_monitoring_in_adult_critically_ill_patients_receiving.pdf
Rights: info:eu-repo/semantics/openAccess