Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

X-ray diffraction at the National Ignition Facility

Title: X-ray diffraction at the National Ignition Facility
Authors: Rygg, JR; Smith, RF; Lazicki, AE; Braun, DG; Fratanduono, DE; Kraus, RG; McNaney, JM; Swift, DC; Wehrenberg, CE; Coppari, F; Ahmed, MF; Barrios, MA; Blobaum, KJM; Collins, GW; Cook, AL; Di Nicola, P; Dzenitis, EG; Gonzales, S; Heidl, BF; Hohenberger, M; House, A; Izumi, N; Kalantar, DH; Khan, SF; Kohut, TR; Kumar, C; Masters, ND; Polsin, DN; Regan, SP; Smith, CA; Vignes, RM; Wall, MA; Ward, J; Wark, J; Zobrist, TL; Arsenlis, A; Eggert, JH
Publisher Information: AIP Publishing
Publication Year: 2020
Collection: Oxford University Research Archive (ORA)
Description: We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2–7 on the periodic table.
Document Type: article in journal/newspaper
Language: English
Relation: https://doi.org/10.1063/1.5129698
DOI: 10.1063/1.5129698
Availability: https://doi.org/10.1063/1.5129698; https://ora.ox.ac.uk/objects/uuid:1354a2f2-2943-445f-b346-261fa5117e59
Rights: info:eu-repo/semantics/openAccess ; CC Attribution (CC BY)
Accession Number: edsbas.5BB2F3B2
Database: BASE