Stability of far field R wave signals in different conditions

Title: Stability of far field R wave signals in different conditions
Authors: Cools, FJC; Van Twembeke, RRC; Backers, J; Verpooten, GA.
Contributors: UCL
Source: Europace, Vol. 5, no. 2, p. 175-183 (2003)
Publisher Information: W B Saunders Co Ltd
Publication Year: 2003
Collection: DIAL@USL-B (Université Saint-Louis, Bruxelles)
Subject Terms: oversensing; far-field; exercise; upright
Description: Aims The presence of far field R wave sensing (FFRS) is usually evaluated in patients with dual chamber pacemakers in supine position. To check if this approach is valid, we tested whether FFRS is consistent both in terms of amplitude threshold and timing characteristics in different daily life conditions. Methods and Results In 42 patients with a DDD pacemaker. the presence. amplitude threshold and timing parameters of FFRS were therefore determined. with patients supine. standing and at peak exercise. Measurements were made of paced and sensed R waves in unipolar and bipolar sensing configurations (at peak exercise only paced R waves and bipolar sensing). After paced R waves (bipolar sensing) amplitude thresholds/time of FFRS after Vpace were 0.32 +/- 0.18 mV/119-139 ms (supine). 0.32 +/- 0.16 mV/114-130 ms (upright) and 0.27 +/- 0.13 mV/121-136 ms (exercise) - with unipolar sensing. this was 0.49 +/- 0.27mV/101-150 ms (Supine). 0.51 +/- 0.29 mV/100-144 ms (upright). After sensed R waves (bipolar sensing) amplitude thresholds/time of FFRS after Vsense were 0.27 +/- 0.18 mV/ 24-42 ms (Supine). 0.29 +/- 0.16 mV/18 to 41 ms (upright) - with unipolar sensing. thresholds were 0.59 +/- 0.32 mV/3-50 ins (supine). 0.59 +/- 0.36 mV/2-58 ms (upright). Conclusion given the lower FFRS thresholds with bipolar sensing. bipolar sensing is superior in avoiding FFRS compared with Unipolar sensing. No differences were found in terms of amplitude thresholds and timing characteristics with patients supine. standing and at peak exercise. Thus. measurements made in the supine position Lire basically sufficient to predict the presence/absence of FFRS under different conditions.
Document Type: article in journal/newspaper
Language: English
Relation: boreal:41127; http://hdl.handle.net/2078.1/41127
DOI: 10.1053/eupc.2002.0299
Availability: http://hdl.handle.net/2078.1/41127; https://doi.org/10.1053/eupc.2002.0299
Accession Number: edsbas.769E3366
Database: BASE