Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Performance of the continuous glucose monitoring system (CGMS) during development of ketosis in patients on insulin pump therapy

Title: Performance of the continuous glucose monitoring system (CGMS) during development of ketosis in patients on insulin pump therapy
Authors: Pfützner, J.; Forst, T.; Butzer, R.; Forst, S.; Weber, M. M.; Pfützner, A. H.; Pfützner, A.
Source: Diabetic Medicine ; volume 23, issue 10, page 1124-1129 ; ISSN 0742-3071 1464-5491
Publisher Information: Wiley
Publication Year: 2006
Collection: Wiley Online Library (Open Access Articles via Crossref)
Description: Aims Ketoacidosis is one of the most severe complications of Type 1 diabetes. Development of ketosis leads to substantial shifts in electrolyte and ion concentrations in the different fluid compartments of the body. This study was performed to investigate the performance of the continuous glucose monitoring device (CGMS) during ketoacidosis. Methods Twelve patients with Type 1 diabetes using continuous subcutaneous insulin infusion (CSII) participated in this trial [10 women, two men; age (mean ± sd ) 34 ± 9 years; disease duration 17 ± 10 years; HbA 1c 7.1 ± 1.0%]. In the morning, patients ate breakfast and the insulin pump was stopped at 11.00 h and restarted after 8 h. Observation parameters during this experiment were: blood glucose (laboratory reference and CGMS), 3‐hydroxy‐butyrate (3‐OHB), pH, Na, pCO 2 , pO 2 , free fatty acids, osmolarity, standard bicarbonate, and lactate. Results Blood glucose increased and reached a plateau within 2 h after pump stop (from 6.2 ± 2.56 to 16.7 ± 4.44 mmol/l, P < 0.001). A constant increase in 3‐OHB (from 0.0 to 0.8 ± 0.5 mmol/l, P < 0.001) and decrease in pH (from 7.43 ± 0.02 to 7.40 ± 0.03, P < 0.05) indicated ketosis development. Na decreased from 141 ± 1.4 to 138 ± 2.8 mmol/l, P < 0.001). Free fatty acids increased from 0.577 ± 0.330 to 1.330 ± 0.462 mmol/l ( P < 0.001). The CGMS values showed excellent agreement with the capillary blood laboratory method during the entire experiment, and a modified error grid analysis revealed that 99.5% of the values were in the clinically acceptable zones A and B. Conclusion The CGMS device was confirmed to be reliable and accurate during the development of hyperglycaemia and ketotic conditions.
Document Type: article in journal/newspaper
Language: English
DOI: 10.1111/j.1464-5491.2006.01945.x
Availability: https://doi.org/10.1111/j.1464-5491.2006.01945.x; https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1111%2Fj.1464-5491.2006.01945.x; https://onlinelibrary.wiley.com/doi/pdf/10.1111/j.1464-5491.2006.01945.x
Rights: http://onlinelibrary.wiley.com/termsAndConditions#vor
Accession Number: edsbas.7EFE3E65
Database: BASE