Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Preliminary Characterization of an Active CMOS Pad Detector for Tracking and Dosimetry in HDR Brachytherapy

Title: Preliminary Characterization of an Active CMOS Pad Detector for Tracking and Dosimetry in HDR Brachytherapy
Authors: Bui, Thi Ngoc Hang; Large, Matthew; Poder, Joel; Bucci, Joseph; Bianco, Edoardo; Giampaolo, Raffaele Aaron; Rivetti, Angelo; Da Rocha Rolo, Manuel; Pastuovic, Zeljko; Corradino, Thomas; Pancheri, Lucio; Petasecca, Marco
Contributors: Bui, Thi Ngoc Hang; Large, Matthew; Poder, Joel; Bucci, Joseph; Bianco, Edoardo; Giampaolo, Raffaele Aaron; Rivetti, Angelo; Da Rocha Rolo, Manuel; Pastuovic, Zeljko; Corradino, Thoma; Pancheri, Lucio; Petasecca, Marco
Publication Year: 2024
Collection: Università degli Studi di Trento: CINECA IRIS
Subject Terms: Brachytherapy; CMOS; source tracking; active pixel; dosimetry; IBIC
Description: We assessed the accuracy of a prototype radiation detector with a built in CMOS amplifier for use in dosimetry for high dose rate brachytherapy. The detectors were fabricated on two substrates of epitaxial high resistivity silicon. The radiation detection performance of prototypes has been tested by ion beam induced charge (IBIC) microscopy using a 5.5 MeV alpha particle microbeam. We also carried out the HDR Ir-192 radiation source tracking at different depths and angular dose dependence in a water equivalent phantom. The detectors show sensitivities spanning from (5.8 ± 0.021) × 10−8 to (3.6 ± 0.14) × 10−8 nC Gy−1 mCi−1 mm−2. The depth variation of the dose is within 5% with that calculated by TG-43. Higher discrepancies are recorded for 2 mm and 7 mm depths due to the scattering of secondary particles and the perturbation of the radiation field induced in the ceramic/golden package. Dwell positions and dwell time are reconstructed within ±1 mm and 20 ms, respectively. The prototype detectors provide an unprecedented sensitivity thanks to its monolithic amplification stage. Future investigation of this technology will include the optimisation of the packaging technique.
Document Type: article in journal/newspaper
Language: English
Relation: info:eu-repo/semantics/altIdentifier/pmid/38276383; info:eu-repo/semantics/altIdentifier/wos/WOS:001151371500001; volume:24; issue:2; journal:SENSORS; https://hdl.handle.net/11572/409535
DOI: 10.3390/s24020692
Availability: https://hdl.handle.net/11572/409535; https://doi.org/10.3390/s24020692; https://www.mdpi.com/1424-8220/24/2/692
Rights: info:eu-repo/semantics/openAccess ; license:Creative commons ; license uri:http://creativecommons.org/licenses/by/4.0/
Accession Number: edsbas.AA3A5C24
Database: BASE