Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Validation of a Neurophysiological-Based Wearable Device (Somfit) for the Assessment of Sleep in Athletes

Title: Validation of a Neurophysiological-Based Wearable Device (Somfit) for the Assessment of Sleep in Athletes
Authors: Gregory D. Roach; Dean J. Miller; Stephanie J. Shell; Kathleen H. Miles; Charli Sargent
Source: Sensors ; Volume 25 ; Issue 7 ; Pages: 2123
Publisher Information: Multidisciplinary Digital Publishing Institute
Publication Year: 2025
Collection: MDPI Open Access Publishing
Subject Terms: athlete; sleep; wearable; polysomnography; validation; agreement; sensitivity; specificity; Bland–Altman; error matrix
Description: The aim of the study was to examine the validity of a neurophysiological-based wearable device, i.e., Somfit (Compumedics Ltd.), for the assessment of sleep in athletes. Twenty-seven athletes (14 F, 13 M, aged 22.3 ± 5.1 years) spent a single night in a sleep laboratory. The participants had 9 h in bed (23:00–08:00) while fitted simultaneously with Somfit and polysomnography (PSG), i.e., the gold standard for the assessment of sleep. Somfit and PSG were used to independently categorise each 30-s epoch of time in bed into one of five states, i.e., wake, stage 1 non-REM sleep (N1), stage 2 non-REM sleep (N2), stage 3 non-REM sleep (N3), or REM sleep. There were large differences between participants in terms of the amount of Somfit data that were successfully captured/scored, so three subsets were considered in the subsequent analyses: unfiltered subset (n = 26)—all participants, except one for whom no Somfit data were captured/scored; good-capture subset (n = 15)—participants for whom > 80% of Somfit data were captured/scored; excellent-capture subset (n = 7)—participants for whom > 99.9% of Somfit data were captured/scored. Agreement for the five-state categorisation of time in bed was calculated as the percentage of PSG epochs correctly scored by Somfit as N1, N2, N3, REM, or wake. Agreement (and Cohen’s kappa) was 63% (0.47) for the unfiltered subset, 66% (0.52) for the good-capture subset, and 79% (0.70) for the excellent-capture subset. These data indicate a moderate–substantial level of agreement between Somfit and PSG for the assessment of sleep in athletes. Wearable devices that can capture valid sleep data may also be used to derive important measures related to the circadian system, such as sleep consistency and social jet lag.
Document Type: text
File Description: application/pdf
Language: English
Relation: Intelligent Sensors; https://dx.doi.org/10.3390/s25072123
DOI: 10.3390/s25072123
Availability: https://doi.org/10.3390/s25072123
Rights: https://creativecommons.org/licenses/by/4.0/
Accession Number: edsbas.ACB1EB68
Database: BASE