Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

In-vivo application of low frequency alternating currents on porcine cervical vagus nerve evokes reversible nerve conduction block

Title: In-vivo application of low frequency alternating currents on porcine cervical vagus nerve evokes reversible nerve conduction block
Authors: Muzquiz, Maria Ivette; Richardson, Lindsay; Vetter, Christian; Smolik, Macallister; Alhawwash, Awadh; Goodwill, Adam; Bashirullah, Rizwan; Carr, Michael; Yoshida, Ken
Contributors: GSK/Galvani Bioelectronics; National Institutes of Health; Familien Hede-Nielsens Fonden; Department of Biomedical Engineering Assistantship Program
Source: Bioelectronic Medicine ; volume 7, issue 1 ; ISSN 2332-8886
Publisher Information: Springer Science and Business Media LLC
Publication Year: 2021
Description: Background This paper describes a method to reversibly block nerve conduction through direct application of a 1 Hz sinusoidal current waveform delivered through a bipolar nerve cuff electrode. This low frequency alternating current (LFAC) waveform was previously shown to reversibly block the effects of vagal pulse stimulation evoked bradycardia in-vivo in the anaesthetised rat model (Mintch et al. 2019). The present work measured the effectiveness of LFAC block on larger caliber myelinated vagal afferent fibers in human sized nerve bundles projecting to changes in breathing rate mediated by the Hering-Breuer (HB) reflex in anaesthetized domestic swine (n=5). Methods Two bipolar cuff electrodes were implanted unilaterally to the left cervical vagus nerve, which was crushed caudal to the electrodes to eliminate cardiac effects. A tripolar recording cuff electrode was placed rostral to the bipolar stimulating electrodes on the same nerve to measure changes in the compound nerve action potentials (CNAP) elicited by the vagal pulse stimulation and conditioned by the LFAC waveform. Standard pulse stimulation was applied at a sufficient level to induce a reduction in breathing rate through the HB reflex. If unblocked, the HB reflex would cause breathing to slow down and potentially halt completely. Block was quantified by the ability of LFAC to reduce the effect of the HB reflex by monitoring the respiration rate during LFAC alone, LFAC and vagal stimulation, and vagal stimulation alone. Results LFAC achieved 87.2 ±8.8% block (n=5) at current levels of 1.1 ±0.3 mA p (current to peak), which was well within the water window of the working electrode. CNAP showed changes that directly correlated to the effectiveness of LFAC block, which manifested itself as the slowing and amplitude reduction of components of the CNAP. Conclusion These novel findings suggest that LFAC is a potential alternative or complementary method to other electrical blocking techniques in clinical applications.
Document Type: article in journal/newspaper
Language: English
DOI: 10.1186/s42234-021-00072-w
DOI: 10.1186/s42234-021-00072-w.pdf
DOI: 10.1186/s42234-021-00072-w/fulltext.html
Availability: http://dx.doi.org/10.1186/s42234-021-00072-w; https://link.springer.com/content/pdf/10.1186/s42234-021-00072-w.pdf; https://link.springer.com/article/10.1186/s42234-021-00072-w/fulltext.html
Rights: https://creativecommons.org/licenses/by/4.0 ; https://creativecommons.org/licenses/by/4.0
Accession Number: edsbas.B4F6B422
Database: BASE