Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Multicenter precision of cortical and trabecular bone quality measures assessed by high‐resolution peripheral quantitative computed tomography

Title: Multicenter precision of cortical and trabecular bone quality measures assessed by high‐resolution peripheral quantitative computed tomography
Authors: Burghardt, Andrew J; Pialat, Jean‐Baptiste; Kazakia, Galateia J; Boutroy, Stephanie; Engelke, Klaus; Patsch, Janina M; Valentinitsch, Alexander; Liu, Danmei; Szabo, Eva; Bogado, Cesar E; Zanchetta, Maria Belen; McKay, Heather A; Shane, Elizabeth; Boyd, Steven K; Bouxsein, Mary L; Chapurlat, Roland; Khosla, Sundeep; Majumdar, Sharmila
Source: Journal of Bone and Mineral Research, vol 28, iss 3
Publisher Information: eScholarship, University of California
Publication Year: 2013
Collection: University of California: eScholarship
Subject Terms: 32 Biomedical and Clinical Sciences (for-2020); 3202 Clinical Sciences (for-2020); Clinical Research (rcdc); Prevention (rcdc); Bioengineering (rcdc); Biomedical Imaging (rcdc); Osteoporosis (rcdc); 3 Good Health and Well Being (sdg); Aged (mesh); Aged; 80 and over (mesh); Bone and Bones (mesh); Feasibility Studies (mesh); Female (mesh); Humans (mesh); Male (mesh); Middle Aged (mesh); Reproducibility of Results (mesh); Tomography; X-Ray Computed (mesh); HR-PQCT; OSTEOPOROSIS; PRECISION; BONE; MICROSTRUCTURE; BONE STRENGTH; MULTICENTER STUDIES
Subject Geographic: 524 - 536
Description: High-resolution peripheral quantitative computed tomography (HR-pQCT) has recently been introduced as a clinical research tool for in vivo assessment of bone quality. The utility of this technology to address important skeletal health questions requires translation to standardized multicenter data pools. Our goal was to evaluate the feasibility of pooling data in multicenter HR-pQCT imaging trials. Reproducibility imaging experiments were performed using structure and composition-realistic phantoms constructed from cadaveric radii. Single-center precision was determined by repeat scanning over short-term (
Document Type: article in journal/newspaper
File Description: application/pdf
Language: unknown
Relation: qt9877z5j5; https://escholarship.org/uc/item/9877z5j5; https://escholarship.org/content/qt9877z5j5/qt9877z5j5.pdf
DOI: 10.1002/jbmr.1795
Availability: https://escholarship.org/uc/item/9877z5j5; https://escholarship.org/content/qt9877z5j5/qt9877z5j5.pdf; https://doi.org/10.1002/jbmr.1795
Rights: public
Accession Number: edsbas.C605B68E
Database: BASE