Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Assessment of the human splanchnic venous volume-pressure relation using radionuclide plethysmography. Effect of nitroglycerin.

Title: Assessment of the human splanchnic venous volume-pressure relation using radionuclide plethysmography. Effect of nitroglycerin.
Authors: Manyari, D E; Wang, Z; Cohen, J; Tyberg, J V
Source: Circulation ; volume 87, issue 4, page 1142-1151 ; ISSN 0009-7322 1524-4539
Publisher Information: Ovid Technologies (Wolters Kluwer Health)
Publication Year: 1993
Description: BACKGROUND No method exists to assess human splanchnic venous function, the most important region in terms of vascular capacity. METHODS AND RESULTS We studied 25 stable patients without heart failure or hypertension to develop a method to assess the splanchnic venous volume-pressure (V-P) relation and to determine the effect of nitroglycerin (GTN). We used blood pool scintigraphy to assess changes in regional splanchnic vascular volume (SVV) and low levels of continuous positive airway pressure (CPAP) to passively alter venous pressure and thus, SVV. We postulated that the relation between SVV and the CPAP used would reflect the capacitance of the splanchnic venous bed and that changes in the position of this relation would provide a relative measurement of any change in capacitance. In 12 patients (group 1), the splanchnic vascular V-P curves were recorded before and 2, 9, and 20 minutes after 0.6 mg sublingual GTN; in eight patients (group 2), recordings were made at similar times before and after sublingual administration of placebo; in five patients (group 3), the hemodynamic effects of CPAP were assessed by means of right and left cardiac catheterization. Right atrial and femoral venous pressures increased (p < 0.001) and cardiac output fell (p < 0.05) during CPAP. There was an apparently linear relation between CPAP and SVV (r=0.74-0.98); SVV increased an average of 7.4 +/- 2.2% (p < 0.001) by 12 cm H2O CPAP: The splanchnic vascular V-P curves were reproducible with minimal variability in SVV (+/- 2%, p > 0.2) in group 2. After administration of GTN, the splanchnic vascular V-P curve shifted away from the pressure axis in a parallel fashion by an average of 9.4 +/- 5.4% (p < 0.001). CONCLUSIONS We have developed a reproducible noninvasive technique that may be used to assess human splanchnic venous V-P relations. We have demonstrated for the first time in humans that GTN exerts its dilatory effect by increasing the unstressed splanchnic venous volume.
Document Type: article in journal/newspaper
Language: English
DOI: 10.1161/01.cir.87.4.1142
DOI: 10.1161/01.CIR.87.4.1142
Availability: https://doi.org/10.1161/01.cir.87.4.1142; https://www.ahajournals.org/doi/pdf/10.1161/01.CIR.87.4.1142
Accession Number: edsbas.D1BEBF90
Database: BASE