Left ventricular blood flow kinetic energy is associated with the six-minute walk test and left ventricular remodelling post valvular intervention in aortic stenosis

Title: Left ventricular blood flow kinetic energy is associated with the six-minute walk test and left ventricular remodelling post valvular intervention in aortic stenosis
Authors: Elhawaz, Alaa; Archer, Gareth T.; Zafar, Hamza; Fidock, Benjamin; Barker, Natasha; Jones, Rachel; Rothman, Alexander; Hose, Rod; Al-Mohammad, Abdallah; Briffa, Norman; Hunter, Steven; Braidley, Peter; Hall, Ian R.; Grech, Ever; van der Geest, Rob J.; Gunn, Julian P.; Swift, Andrew J.; Wild, James M.; Garg, Pankaj
Publication Year: 2021
Collection: University of East Anglia: UEA Digital Repository
Description: Background: Left ventricular (LV) kinetic energy (KE) assessment by four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) may offer incremental value over routine assessment in aortic stenosis (AS). The main objective of this study is to investigate the LV KE in patients with AS before and after the valve intervention. In addition, this study aimed to investigate if LV KE offers incremental value for its association to the six-minute walk test (6MWT) or LV remodelling post-intervention. Methods: We recruited 18 patients with severe AS. All patients underwent transthoracic echocardiography for mean pressure gradient (mPG), CMR including 4D flow and 6MWT. Patients were invited for post-valve intervention follow-up CMR at 3 months and twelve patients returned for follow-up CMR. KE assessment of LV blood flow and the components (direct, delayed, retained and residual) were carried out for all cases. LV KE parameters were normalised to LV end-diastolic volume (LVEDV). Results: For LV blood flow KE assessment, the metrics including time delay (TD) for peak E-wave from base to mid-ventricle (14±48 vs. 2.5±9.75 ms, P=0.04), direct (4.91±5.07 vs. 1.86±1.72 μJ, P=0.01) and delayed (2.46±3.13 vs. 1.38±1.15 μJ, P=0.03) components of LV blood flow demonstrated a significant change between pre- and post-valve intervention. Only LV KEiEDV (r=-0.53, P
Document Type: article in journal/newspaper
File Description: application/pdf
Language: English
ISSN: 2223-4292
Relation: https://ueaeprints.uea.ac.uk/id/eprint/82127/1/Published_Version.pdf; Elhawaz, Alaa, Archer, Gareth T., Zafar, Hamza, Fidock, Benjamin, Barker, Natasha, Jones, Rachel, Rothman, Alexander, Hose, Rod, Al-Mohammad, Abdallah, Briffa, Norman, Hunter, Steven, Braidley, Peter, Hall, Ian R., Grech, Ever, van der Geest, Rob J., Gunn, Julian P., Swift, Andrew J., Wild, James M. and Garg, Pankaj (2021) Left ventricular blood flow kinetic energy is associated with the six-minute walk test and left ventricular remodelling post valvular intervention in aortic stenosis. Quantitative Imaging in Medicine and Surgery, 11 (4). pp. 1470-1482. ISSN 2223-4292
Availability: https://ueaeprints.uea.ac.uk/id/eprint/82127/; https://ueaeprints.uea.ac.uk/id/eprint/82127/1/Published_Version.pdf
Rights: cc_by_nc_nd
Accession Number: edsbas.D7691678
Database: BASE