Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Improved Limits on the 21 cm Signal at z = 6.5-7.0 with the Murchison Widefield Array Using Gaussian Information

Title: Improved Limits on the 21 cm Signal at z = 6.5-7.0 with the Murchison Widefield Array Using Gaussian Information
Authors: Trott, CM; Nunhokee, CD; Null, D; Barry, N; Qin, Y; Wayth, RB; Line, JLB; Jordan, CH; Pindor, B; Cook, JH; Bowman, J; Chokshi, A; Ducharme, J; Elder, K; Guo, Q; Hazelton, BJ; Hidayat, W; Ito, T; Jacobs, D; Jong, E; Kolopanis, M; Kunicki, T; Lilleskov, E; Morales, MF; Pober, J; Selvaraj, A; Shi, R; Takahashi, K; Tingay, SJ; Webster, RL; Yoshiura, S; Zheng, Q
Publisher Information: American Astronomical Society
Publication Year: 2025
Collection: The University of Melbourne: Digital Repository
Description: We explore the properties of interferometric data from high-redshift 21 cm measurements using the Murchison Widefield Array (MWA). These data contain the redshifted 21 cm signal, contamination from continuum foreground sources, and radiometric noise. The 21 cm signal from the Epoch of Reionization (EoR) is expected to be highly Gaussian, which motivates the use of the power spectrum as an effective statistical tool for extracting astrophysical information. We find that foreground contamination introduces non-Gaussianity into the distribution of measurements and then use this information to separate Gaussian from the non-Gaussian signal. We present improved upper limits on the 21 cm EoR power spectrum from the MWA using a Gaussian component of the data, based on the existing analysis from C. D. Nunhokee et al. 2025. This is extracted as the best-fitting Gaussian to the measured data. Our best 2σ (thermal+sample variance) limit for 268 hr of data improves from (30.2 mK) 2 to (23.0 mK) 2 at z = 6.5 for the East-West polarization, and from (39.2 mK) 2 to (21.7 mK) 2 = 470 mK 2 in North-South. The best limits at z = 6.8 (z = 7.0) improve to P < (25.9 mK) 2 (P < (32.0 mK) 2 ) and k = 0.18h Mpc −1 (k = 0.21h Mpc −1 ). Results are compared with realistic simulations, which indicate that leakage from foreground contamination is a source of the non-Gaussian behavior.
Document Type: article in journal/newspaper
Language: unknown
ISSN: 0004-637X
Relation: https://hdl.handle.net/11343/363553
Availability: https://hdl.handle.net/11343/363553
Rights: https://creativecommons.org/licenses/by/4.0 ; CC-BY
Accession Number: edsbas.DA7CE9B6
Database: BASE