Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Hyperpolarized 129 Xe multi‐slice imaging of the human brain using a 3D gradient echo pulse sequence

Title: Hyperpolarized 129 Xe multi‐slice imaging of the human brain using a 3D gradient echo pulse sequence
Authors: Grynko, Vira; Shepelytskyi, Yurii; Li, Tao; Hassan, Ayman; Granberg, Karl; Albert, Mitchell S.
Contributors: Ontario Research Foundation; Northern Ontario Academic Medicine Association
Source: Magnetic Resonance in Medicine ; volume 86, issue 6, page 3175-3181 ; ISSN 0740-3194 1522-2594
Publisher Information: Wiley
Publication Year: 2021
Collection: Wiley Online Library (Open Access Articles via Crossref)
Description: Purpose To demonstrate the possibility of performing multi‐slice in‐vivo human brain MRI using hyperpolarized (HP) xenon‐129 ( 129 Xe) in two different orientations and to calculate the signal‐to‐noise ratio (SNR). Methods Two healthy female participants were imaged during a single breath‐hold of HP 129 Xe using a Philips Achieva 3.0T MRI scanner (Philips, Andover, MA). Each HP 129 Xe multi‐slice brain image was acquired during separate HP 129 Xe breath‐holds using 3D gradient echo (GRE) imaging. The acquisition started 10 s after the inhalation of 1 L of HP 129 Xe. Overall, four sagittal and three axial images were acquired (seven imaging sessions per participant). The SNR was calculated for each slice in both orientations. Results The first ever HP 129 Xe multi‐slice images of the brain were acquired in axial and sagittal orientations. The HP 129 Xe signal distribution correlated well with the gray matter distribution. The highest SNR values were close in the axial and sagittal orientations (19.46 ± 3.25 and 18.76 ± 4.94, respectively). Additionally, anatomical features, such as the ventricles, were observed in both orientations. Conclusion The possibility of using multi‐slice HP 129 Xe human brain magnetic resonance imaging was demonstrated for the first time. HP 129 Xe multi‐slice MRI can be implemented for brain imaging to improve current diagnostic methods.
Document Type: article in journal/newspaper
Language: English
DOI: 10.1002/mrm.28932
Availability: https://doi.org/10.1002/mrm.28932; https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.28932; https://onlinelibrary.wiley.com/doi/full-xml/10.1002/mrm.28932
Rights: http://creativecommons.org/licenses/by/4.0/
Accession Number: edsbas.EA1C5FF
Database: BASE