Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Performance of the Tachyon Time-of-Flight PET Camera

Title: Performance of the Tachyon Time-of-Flight PET Camera
Authors: Peng, Q; Choong, W-S; Vu, C; Huber, JS; Janecek, M; Wilson, D; Huesman, RH; Qi, Jinyi; Zhou, Jian; Moses, WW
Source: IEEE Transactions on Nuclear Science, vol 62, iss 1
Publisher Information: eScholarship, University of California
Publication Year: 2015
Collection: University of California: eScholarship
Subject Terms: 5106 Nuclear and Plasma Physics (for-2020); 51 Physical Sciences (for-2020); Biomedical Imaging (rcdc); Bioengineering (rcdc); Signal-to-noise ratio; time-of-flight; timing resolution; 0202 Atomic; Molecular; Nuclear; Particle and Plasma Physics (for); 0299 Other Physical Sciences (for); 0903 Biomedical Engineering (for); Nuclear & Particles Physics (science-metrix)
Subject Geographic: 111 - 119
Description: We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 × 25 mm2 side of 6.15 × 6.15 × 25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.
Document Type: article in journal/newspaper
File Description: application/pdf
Language: unknown
Relation: qt27d48270; https://escholarship.org/uc/item/27d48270; https://escholarship.org/content/qt27d48270/qt27d48270.pdf
DOI: 10.1109/tns.2014.2375176
Availability: https://escholarship.org/uc/item/27d48270; https://escholarship.org/content/qt27d48270/qt27d48270.pdf; https://doi.org/10.1109/tns.2014.2375176
Rights: public
Accession Number: edsbas.EBB08B1D
Database: BASE