Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke

Title: Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke
Authors: Koopman, Miou S; Berkhemer, Olvert A; Geuskens, Ralph R E G; Emmer, Bart J; van Walderveen, Marianne A A; Jenniskens, Sjoerd F M; van Zwam, Wim H; van Oostenbrugge, Robert J; van der Lugt, Aad; Dippel, Diederik W J; Beenen, Ludo F; Roos, Yvo B W E M; Marquering, Henk A; Majoie, Charles B L M; on behalf of the MR CLEAN Trial Investigators; Fransen, Puck SS; Beumer, Debbie; Van den berg, Lucie A; Lingsma, Hester F; Yoo, Albert J; Schonewille, Wouter J; Vos, Jan Albert; Nederkoorn, Paul J; Wermer, Marieke JH; Staals, Julie; Hofmeijer, Jeannette; Van oostayen, Jacques A; Lycklama ànijeholt, Geert J; Boiten, Jelis; Brouwer, Patrick A; De Bruijn, Sebastiaan F; Van Dijk, Lukas C; Kappelle, L Jaap; Lo, Rob H; Van Dijk, Ewoud J; Vries, Joost De; Van Tuijl, Julia H; J van Rooij, Willem Jan; Van den berg, Jan SP; Van Hasselt, Boudewijn AAM; Aerden, Leo AM; Dallinga, RenéJ; Visser, Marieke C; Bot, Joseph CJ; Vroomen, Patrick C; Eshghi, Omid; Schreuder, Tobien HCML; Heijboer, Roel JJ; Keizer, Koos; Tielbeek, Alexander V; Den Hertog, Heleen M; Gerrits, Dick G; Van den Berg, Renske M; Karas, Giorgos B; Steyerberg, Ewout W; Flach, Zwenneke; Sprengers, Marieke ES; Den Berg, RenéVan; Koudstaal, Peter J
Publisher Information: BMJ Publishing Group Ltd
Publication Year: 2019
Collection: HighWire Press (Stanford University)
Subject Terms: Neuroimaging
Description: Background and purpose CT perfusion (CTP) might support decision making in patients with acute ischemic stroke by providing perfusion maps of ischemic tissue. Currently, the reliability of CTP is hampered by varying results between different post-processing software packages. The purpose of this study is to compare ischemic core volumes estimated by IntelliSpace Portal (ISP) and syngo.via with core volumes as estimated by RAPID. Methods Thirty-five CTP datasets from patients in the MR CLEAN trial were post-processed. Core volumes were estimated with ISP using default settings and with syngo.via using three different settings: default settings (method A); additional smoothing filter (method B); and adjusted settings (method C). The results were compared with RAPID. Agreement between methods was assessed using Bland–Altman analysis and intraclass correlation coefficient (ICC). Accuracy for detecting volumes up to 25 mL, 50 mL, and 70 mL was assessed. Final infarct volumes were determined on follow-up non-contrast CT. Results Median core volume was 50 mL with ISP, 41 mL with syngo.via method A, 20 mL with method B, 36 mL with method C, and 11 mL with RAPID. Agreement ranged from poor (ISP: ICC 0.41; method A: ICC 0.23) to good (method B: ICC 0.83; method C: ICC 0.85). The bias (1.8 mL) and limits of agreement (−27, 31 mL) were the smallest with syngo.via with additional smoothing (method B). Agreement for detecting core volumes ≤25 mL with ISP was 54% and 57%, 85% and 74% for syngo.via methods A, B, and C, respectively. Conclusion Best agreement with RAPID software is provided by syngo.via default settings with additional smoothing. Moreover, this method has the highest agreement in categorizing patients with small core volumes.
Document Type: text
File Description: text/html
Language: English
Relation: http://jnis.bmj.com/cgi/content/short/11/12/1249; http://dx.doi.org/10.1136/neurintsurg-2019-014822
DOI: 10.1136/neurintsurg-2019-014822
Availability: http://jnis.bmj.com/cgi/content/short/11/12/1249; https://doi.org/10.1136/neurintsurg-2019-014822
Rights: Copyright (C) 2019, Society of NeuroInterventional Surgery
Accession Number: edsbas.ECA346C4
Database: BASE