Katalog Plus
Bibliothek der Frankfurt UAS
Bald neuer Katalog: sichern Sie sich schon vorab Ihre persönlichen Merklisten im Nutzerkonto: Anleitung.
Dieses Ergebnis aus BASE kann Gästen nicht angezeigt werden.  Login für vollen Zugriff.

The Impact of Cataract, and Its Surgical Removal, on Measures of Macular Pigment Using the Heidelberg Spectralis HRAþOCT MultiColor Device

Title: The Impact of Cataract, and Its Surgical Removal, on Measures of Macular Pigment Using the Heidelberg Spectralis HRAþOCT MultiColor Device
Authors: Kwadwo Owusu Akuffo; John M Nolan; Jim Stack; Rebecca Power; Clare Kirwan; Rachel Moran; Laura Corcoran; Niamh Owens; Stephen Beatty
Contributors: The Pennsylvania State University CiteSeerX Archives
Source: http://iovs.arvojournals.org/data/Journals/IOVS/935270/i1552-5783-57-6-2552.pdf.
Publication Year: 2016
Collection: CiteSeerX
Description: PURPOSE. To investigate the effect of cataract (and cataract surgery) on macular pigment (MP) measurements using the Heidelberg Spectralis HRAþOCT MultiColor device. METHODS. Thirty-six patients (age, 54-87 years) scheduled for cataract surgery at the Institute of Eye Surgery, Ireland, were enrolled in this study. Cataracts were graded using the Lens Opacities Classification System (LOCS) III, and surgery was performed using standard phacoemulsification technique with implantation of a Tecnis ZCB00 or Tecnis ZCT intraocular lens. Macular pigment was measured before and after cataract surgery in the operated (study) eye and in the fellow (control) eye. RESULTS. In the study eye, there was statistically significant disagreement in measures of MP taken before and after surgery. At all eccentricities, and also for MP volume, the postsurgery measurements were significantly (P < 0.05) greater, ranging from an average 16% greater at 1.728 to an average 35% greater at 0.238 eccentricity. Eyes exhibiting large disagreement between pre-and postsurgery measurements at a given eccentricity also generally exhibited substantial disagreement at other eccentricities. Overall severity of cataract contributed to greater disagreement between pre-and postoperative measures of MP, as did grade of nuclear opalescence, nuclear color, and posterior subcapsular cataract. In control eyes, there was no statistically significant disagreement in terms of measures of MP taken before and after cataract surgery (P > 0.05 for all; 1-sample t-test). CONCLUSIONS. Macular pigment measurements using the Spectralis are affected by cataract. Accordingly, we recommend that cataract be graded when measuring MP with a device that utilizes dual-wavelength fundus autofluorescence and propose the employment of a correction factor to compensate for cataract when measuring MP.
Document Type: text
File Description: application/pdf
Language: English
Relation: http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1081.8042
Availability: http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1081.8042; http://iovs.arvojournals.org/data/Journals/IOVS/935270/i1552-5783-57-6-2552.pdf
Rights: Metadata may be used without restrictions as long as the oai identifier remains attached to it.
Accession Number: edsbas.FB0F93CA
Database: BASE